Top Nebulizer for Infants with Mask

Med2000 Penguin

Med2000 PenguinAdvantages: This nebulizer has no age constrictions. A kit includes a nebulizer mask produced for infants and children up to 3 years old. There are 3 modes of operation of a nebulizer camera with aerosol flow control. This device is attractive in price, appearance in the form of a toy. It has a storage bag for convenient transportation. Its warranty is extended up to 5 years.

Disadvantages: heavy noise.

Weight: 1640 g
Size: 227/175/119 mm
Charge: ~220-240 Watt
Tension: 2,5 Bar
Inhalation rate: 8 l/min
Chamber volume: 7 ml
Sputtering rate: 0.2-0.6 ml/min
Noise threshold: 60 dBA (background noise is lower than 40 dBA)
Operation mode № 1: 1-3 μ (piston С)
Operation mode № 2: 3-5 μ (piston B)
Operation mode № 3: 5-10 μ (piston A)
Active/Inactive: 30 min/30 min
Set: compressor, nebulizer chamber, silicon tube, an adult mask for a nebulizer, a mask for infant, handy carrying bag, mouthpiece, replaceable filters, 3 pistons, adapter, nasal cannula, nasal nozzle
Warranty: 5 years

Flaem Nuova Lella ladybug

Flaem Nuova Lella ladybugAdvantages: storage bag, three modes of operation, the form of a toy, the choice of colors inhaler, Italy production, nasal irrigator.

Disadvantages: price, operation with a huge noise.

Weight: 1600 g
Size: 210/160/130 mm
Charge: 220 Watt, 50 Hz
Tension: 2,5 Bar
Nebulizer chamber volume: nebulizer: 2-8 ml
inhaler: 10 ml
Sputtering rate: 0.2-0.6 ml/min
Noise threshold: 60 dBA
Working power: 140 Watt

Med2000 Cat

Med2000 CatAdvantages: advanced equipment, 3 modes of operation, the nebulizer chamber with aerosol flow control, attractive appearance, the presence of a bag for storage. The warranty is up to 5 years. Affordable price.

Disadvantages: noisy performance.

Weight: 1500 g
Size: 235/172/152.5 mm
Charge: ~220-240 Watt
Tension: 2,5 Bar
Airflow rate: 8 l/min
Nebulizer chamber volume: 7 ml
Spluttering speed: 0,2- 06 ml/min
Noise threshold: 60 dBA (background noise is lower than 40 dBA)
Operation mode № 1: 1-3 μ (piston С)
Operation mode № 2: 3-5 μ (piston B)
Operation mode № 3: 5-10 μ (piston A)
Active/inactive: 30 min/30 min
Set: compressor, nebulizer chamber, silicon tube, adult mask, nebulizer mask for toddlers, handy carrying bag, mouthpiece, replaceable filters, 3 pistons, adapter, nasal cannula, nasal nozzle
Warranty: 5 years

Omron C-24

Omron C-24Advantages: compact, attractive appearance, minimal loss of drugs during the inhalation, nebulizer machine with a mask.

Disadvantages: price, single-mode nebulizer chamber without newborn masks.

Weight: 270 g
Size: 142/92/98 mm
Charge: ~220, 50 Hz
Nebulizer chamber volume: 7 ml
Capacity: 0,06 ml/min
Noise threshold: 60 dBA (background noise is lower than 40 dBA)
Size of particles: 3 μ
Acute working time: 20 min
Cord length: 1 m

Med2000 CicoBoy

Med2000 CicoBoyAdvantages: 3 modes of operation, a nebulizer chamber with a flow controller. It looks attractive, there is the choice of inhaler colors. The offered warranty lasts up to 5 years, Italy production.

Disadvantages: compressor works with noise, there is no storage bag.

Weight: 1300 g
Size: 120/150/175 mm
Charge: ~220-240 Watt
Tension: ~2.5 Bar
Air outflow: 8 l/min
Nebulizer chamber volume: 7 ml
Spluttering speed: 0,25 ml/min
Noise threshold:  up to 54 dB
Operation mode № 1: 1 – 3 μ
Operation mode № 2: 3 – 5 μ
Operation mode № 3: 5 – 10 μ
Set: 2 nebulizer masks (children, adults), mouthpiece, nebulizer, silicon tube, filter, 3 pistons, nasal cannula
Active/inactive: 30 min/30 min
Warranty: 5 years

B.Well train

B.Well trainAdvantages: attractive appearance, price, pediatric nebulizer masks, color applications.

Disadvantages: single-mode nebulizer chamber, noise compressor, no storage bag.

Weight: 1786 g
Size: 120/150/175 mm
Charge: ~220-240 Watt
Tension: 230 Watt, 50 Hz, 1A
Nebulizer chamber volume: 2-8 ml
Spluttering speed: 0,4 ml/min
Noise threshold: up to 54 dB
Size of particles (ММАD) 3,16 μ
The remaining volume of the nebulizer chamber: 1 ml
Operation conditions: t min +10 -max +40
Active/inactive: 30 min/30 min
Humidity: Min 10% RH- max 95 RH
Air-pressure: 700 hPa-1060 hPa
Storage conditions: t min -25- max +70

How to use a nebulizer with a mask?

  • Wash hands properly before handling.
  • Put all the details of the device together according to the instructions.
  • Pour the required volume of medicinal solution warmed to room temperature into the nebulizer chamber.
  • Close the chamber, use a nebulizer mask.
  • Connect the tank and the compressor with a silicone tube.
  • Turn on the unit and inhale the vapors for 7-10 minutes until the complete absence of the solution.
  • Inhalations are carried out 1.5-2 hours after eating.
  • Inhalations and exhalations are made through the nose in the case of upper respiratory tract diseases.
  • For diseases of the larynx, trachea, lungs, or bronchi, after a deep breath from the mouth, breathing is held for a couple of seconds and exhaled by the nose.
  • Turn off the compressor, disconnect the inhaler and take it apart and wash it.
  • The dried device is wrapped with a clean towel.